Programmable solid state pressure, differential pressure, and temperature devices with local indication for general service, hazardous area, or harsh environment applications. 4-20 mA transmitter-only, switch-only, or hybrid transmitter-switch models, front-panel digital process display and keypad adjustment, adjustable differential, I Am Working self-diagnostics, NEMA 4X/IP66 epoxy-coated aluminum alloy 360 enclosure with tempered glass window, UL listed, CSA approved, cUL certified, CE compliant.
United Electric's One Series provides explosion-, flame-proof, intrinsically safe, and non-incendive devices to monitor gauge pressure, differential pressure, or temperature for critical alarm and shutdown applications in general service or harsh, hazardous environments. With a digital process display and available 4-20 mA output, the One Series can provide the functions of a switch, a gauge, and a transmitter with only one connection to the process.
UE One Series is available in two-wire analog loop powered, two-wire discrete input powered, and externally powered solid state switch models, and as switch-only, transmitter-only, or transmitter/switch versions. Transmitter and hybrid transmitter-switch One Series now feature HART® communications so you can program or troubleshoot without removing the enclosure cover to maintain device integrity, even in explosive environments.
Field-proven in thousands of applications like pumps and compressors, lubricating oil monitoring, hydraulic oil pressure, filter monitoring, and plant upgrades as drop-in replacements for mechanical switches.
- Switch only, transmitter only, or hybrid transmitter/switch models available
- Two switch-only models available: High voltage, low current for compatibility to worldwide DCS and PLC systems, and high voltage, high current for switching high level loads directly at the measurement point
- Solid state switch-only models replace mechanical switches for cost-effective upgrades using existing wiring
- NAMUR standard and HART® enabled transmitter; 4-20 mA output plus programmable switch for process monitoring, alarm, and shutdown
- Adjustable Ranges: Pressure -14.7 to 6000 PSI, Temperature -40° to 1000°F, Differential Pressure 0 to 200 PSID
- Configurable "I Am Working" self-diagnostics ensure the instrument is functioning properly
- Display and keypad provide easy, fast, secure field programming without taking the device out of service
- Programmable setpoint and deadband provide versatile, accurate, repeatable alarm and shutdown switching without "wet" calibrations on a pressure test stand
- All models UL, CSA approved for Class I Div 1, Class II Div 1, Class III, plus Class 2 Zone 1, and Class 1 Zone 2 environments
Model Selection Guide
Use this table to find the right model for your application. Looking for other ranges or configurations? Don't see the option you need? Call a Lesman sales specialist at 800-953-7626.
Description | Catalog Number |
Availability | ||||
---|---|---|---|---|---|---|
One Series Intrinsically Safe, Flameproof, and Non-Incendive Electronic Transmitter/Switch | ||||||
Discrete input powered two-wire switch, 7.8-50 VDC @ 0.1A Discrete input powered two-wire switch, 70-240 VAC/VDC @0.1A External powered four-wire switch, 70-240 VAC/VDC @0.15-10A Loop-powered HART transmitter, two programmable relays, 0-280 VAC/VDC @ 0.3 A Loop-powered HART transmitter |
1XSWLL 1XSWHL 1XSWHH 1XTXSW 1XTX00 |
↓ ↓ ↓ ↓ ↓ |
↓ ↓ ↓ ↓ ↓ |
↓ ↓ ↓ ↓ ↓ |
||
Sensor Type and Range Selection | ||||||
Pressure Sensor, 316L Stainless Steel, Welded Diaphragm, 1/2" NPTF Differential Pressure Sensor, 316L Stainless Steel, Welded Diaphragm, 1/4" NPTM Temperature Sensor, 100Ω RTD, 316SS Sheath, 0.25" OD |
P K T |
↓ |
↓ |
↓ |
||
Pressure Ranges |
Range | Max. Overrange | ||||
-14.7 to 30 PSI -14.7 to 100 PSI 0-5 PSI 0-15 PSI 0-30 PSI 0-50 PSI 0-100 PSI 0-300 PSI 0-500 PSI 0-1000 PSI 0-3000 PSI 0-4500 PSI 0-6000 PSI |
60 PSI 200 PSI 10 PSI 30 PSI 60 PSI 100 PSI 200 PSI 600 PSI 1000 PSI 2000 PSI 6000 PSI 9000 PSI 12000 PSI |
-_ 06 -_ 08 -_ 10 -_ 11 -_ 12 -_ 13 -_ 14 -_ 15 -_ 16 -_ 17 -_ 18 -_ 19 -_ 20 |
• • • • • • • • • • • • • |
|||
Differential Pressure Ranges |
0-5 PSID 0-50 PSID 0-100 PSID 0-200 PSID |
10 PSID 100 PSID 200 PSID 400 PSID |
-_ 10 -_ 11 -_ 12 -_ 13 |
• • • • |
||
Temperature Range and Configuration | ||||||
Local Stem-Mount Sensor |
-40° to 450°F, 4" probe length -40° to 450°F, 6" probe length -40° to 450°F, 10" probe length |
-_ L1 -_ L2 -_ L3 |
• • • |
|||
Remote Sensor Fixed Cable Length |
-300° to 200°F, 2.5" probe length, 6' MI cable -40° to 450°F, 6" probe length, 6' Teflon® cable -40° to 1000°F, 2.5" probe length, 6' MI cable |
-_ C1 -_ R1 -_ H1 |
• • • |
|||
Remote Sensor Custom Cable Length (Specify When Ordering) |
-300° to 200°F, 2.5" probe length, up to 30' MI extension cable -40° to 450°F 6" probe length, up to 30' Teflon® extension cable -40° to 1000°F, 2.5" probe length, up to 30' MI extension cable |
-_ CC -_ RC -_ HC |
• • • |
Lesman Instrument Company on YouTube
Video is a great way to learn about instruments and technology, and it's available whenever you need it. Watch step-by-step instructions on how to configure a transmitter, tune a controller, or troubleshoot a safety valve. We'll post videos we create, and those our manufacturer partners share with us, so you don't have to look in multiple places to find the video training you need.
Subscribe to Lesman's YouTube channel, and you'll get email notifications as soon as we add new training videos and webinars.
HART | Yes |
---|---|
Measured Variable | Differential Pressure, Gauge Pressure, Temperature |
Enclosure/Construction | NEMA 4X, Div 1 Hazardous, Div 2 Hazardous |
Switch Output | SPST, MOSFET/SSR, 4-20 mA, HART |
Sensor Type | RTD, Strain Gage |
Adjustment | External Adjustment |
Measuring Range | -14.7 to 6000 PSIG, 0 to 200 PSID, -40° to 1000° F |
To build your complete part number, make a selection from each table section below. Your completed model and its price will appear below the table. If you don't see the options you need, call us.
Results
Please complete your model selections. |