Rugged pressure and temperature switches for Class I/II, Div 2 hazardous areas or corrosive atmospheres. Single SPDT switch output (DPDT optional), internal adjustment, reference scale, NEMA 4X enclosure, sensor materials to meet media and environmental requirements, UL, NACE approved, CE compliant.
Approved for Division 2 hazardous locations and corrosive atmospheres, United Electric's 117 series switches can be used to measure vacuum, pressure, differential pressure, and temperature in demanding applications in steel and aluminum mills, chemical and petrochemical plants, pulp and paper mills, wastewater treatment, midstream and downstream oil and gas, and pharmaceutical manufacturing plants.
The UE 117's compact, epoxy coated enclosure and hermetically sealed snap switch provide superior corrosion resistance within the harshest environments, isolating the contacts from moisture, humidity, and chemical atmospheres. Sensors are available in materials from all welded (NACE-compliant) stainless steel to elastomer diaphragms.
- Single SPDT hermetically sealed snap action switch standard, DPDT optional
- Pressure ranges from 30" HgVac to 3500 PSI with internal setpoint lock and high/low reference scale
- Temperature ranges from -120° to 640° F with reference dial
- NEMA 4X epoxy-coated diecast aluminum enclosure
- Polished stainless steel flush-mount sensors
- 1/4" or 1/2" NPTF brass or stainless steel process connections
- Enclosed terminal block wiring
- UL Listed Class I, Division 2, Class II, Division 2, Class III Certified, CE Compliant, NACE Approved (welded diaphragm models), ATEX Approved
Model Selection Guide
Use this table to find the right model for your application. Looking for other ranges, wetted materials or connection sizes? Don't see the option you need? Call a Lesman sales specialist at 800-953-7626.
- UE 117 Series Pressure Switches
- UE 117 Series Temperature Switches
- Need a UE 117 Series for Differential Pressure? Call for Ranges, Pricing, and Lead Times.
Sensor | Pressure Connection |
Adjustable Setpoint Range |
Deadband (Max at Top 25% Span) |
Proof Pressure |
Click for Price and Availability |
|
---|---|---|---|---|---|---|
Material | Size | |||||
H117: One SPDT Output, NEMA 4X Diecast Aluminum Enclosure, Internal Adjustment with High/Low Reference Scale, 303 Stainless Steel Spring Exposed to Media | ||||||
Phosphor Bronze Bellows | Nickel-Plated Brass | 1/4" NPTF | 30" HgVac to 0 PSI | 2" to 5" Hg | 30 PSI | H117-218 |
H117: One SPDT Output, NEMA 4X Diecast Aluminum Enclosure, Internal Adjustment with High/Low Reference Scale, 0.72" Orifice for Clean-Out Purposes | ||||||
Buna-N Diaphragm and O-Ring |
Epoxy-Coated Aluminum |
1/2" NPTF | 300" Vac to 0" WC 10" Vac to 10" WC 50" Vac to 50" WC 0.5" to 5" WC 2.5" to 50" WC 10" to 250" WC |
0.8" to 32" WC 0.4" to 2.4" WC 0.4" to 12" WC 0.4" to 1.2" WC 0.4" to 3.2" WC 0.4" to 24" WC |
400 PSI | H117-520 H117-521 H117-522 H117-523 H117-524 H117-525 |
H117: One SPDT Output, NEMA 4X Diecast Aluminum Enclosure, Internal Adjustment with High/Low Reference Scale, 0.72" Orifice for Clean-Out Purposes; NACE MR-0175 Compliant (* H117-194 is not NACE-Compliant) | ||||||
Welded 316L Stainless Steel Diaphragm |
Welded 316L Stainless Steel |
1/2" NPTF | 1 to 20 PSI 2 to 50 PSI 4 to 100 PSI 8 to 200 PSI |
0.1 to 3 PSI 0.1 to 5 PSI 0.1 to 10 PSI 0.1 to 15 PSI |
1000 PSI | H117-171 H117-172 H117-173 H117-174 |
Welded 316L Stainless Steel Diaphragm |
Welded 316L Stainless Steel |
1/2" NPTF | 5 to 30 PSI 10 to 100 PSI 15 to 300 PSI 20 to 500 PSI 80 to 1700 PSI |
3 to 8 PSI (10 PSI) 3 to 30 PSI (45 PSI) 10 to 40 PSI (60 PSI) 15 to 45 PSI (75 PSI) 5 to 120 PSI (200 PSI) |
2500 PSI | H117-190 H117-191 H117-192 H117-193 H117-194 * |
H117: One SPDT Output, NEMA 4X Diecast Aluminum Enclosure, Internal Adjustment with High/Low Reference Scale, Mates with Customer-Supplied Tri-Clamp® Fitting | ||||||
Welded 316L Stainless Steel Diaphragm |
Welded 316L Stainless Steel |
1.5" Flush Mount |
5 to 30 PSI 10 to 100 PSI 15 to 300 PSI |
3 to 15 PSI 3 to 36 PSI 9 to 66 PSI |
1500 PSI | H117-565 H117-566 H117-567 |
Adjustable Setpoint Range | Maximum Temperature | Scale Division | Bulb OD x Stem Length |
Click for Price and Availability |
|||
---|---|---|---|---|---|---|---|
°F | °C | °F | °C | °F | °C | ||
E117: One SPDT Output, NEMA 4X Diecast Aluminum Enclosure Internal Adjustment with Reference Scale, 304 Stainless Steel Bulb and 6-Foot Capillary | |||||||
-120° to 100° -20° to 80° 25° to 100° 30° to 250° 100° to 400° 350° to 640° |
-84.4° to 37.8° -28.9° to 26.7° -3.9° to 37.8° -1.1° to 121.1° 37.8° to 204.4° 176.7° to 337.8° |
150° 130° 150° 300° 450° 690° |
65.6° 54.4° 65.6° 148.9° 232.2° 365.6° |
10° 5° 2° 10° 10° 10° |
5° 2° 1° 5° 5° 5° |
3/8" OD x 2-5/8" 3/8" OD x 5" 3/8" OD x 6-3/4" 3/8" OD x 2-5/8" 3/8" OD x 2-1/8" 3/8" OD x 3-1/4" |
E117-2BSA E117-5BS E117-4BS E117-2BSB E117-3BS E117-8BS |
Adjustable Setpoint Range | Maximum Temperature | Scale Division | Stem NPT x
Length Below 1/2" Thread |
Click for Price and Availability |
|||
°F | °C | °F | °C | °F | °C | ||
B117: One SPDT Output, NEMA 4X Diecast Aluminum Enclosure Internal Adjustment with Reference Scale, Nickel-Plated Brass Stem | |||||||
0 to 225 200 to 425 |
-17.8 to 107.2 93.3 to 218.3 |
275 475 |
135 246.1 |
10 10 |
5 5 |
9/16" OD x 1-7/8" BT 9/16" OD x 1-7/8" BT |
B117-120 B117-121 |
Measured Variable | Gauge Pressure, Vacuum/Compound Pressure, Temperature |
---|---|
Enclosure/Construction | NEMA 4X, Div 2 Hazardous |
Switch Output | SPDT, DPDT |
Sensor Type | Bellows, Diaphragm, Immersion Stem, Bulb and Capillary |
Adjustment | Internal Adjustment, Reference Scale/Dial |
Measuring Range | 30" HgVac to 3500 PSI, -120° to 640° F |