Electromagnetic flow sensors designed to meet groundwater, drinking water, wastewater, water distribution, irrigation, and sewage or sludge applications. Available in pipe diameters from 0.5" to 48" for media temperatures 14° to 158° F and operating pressures to 580 PSI. Complete flowmeter includes local- or remote-mounted FMT020 flow transmitter, ordered separately. Can be installed in zero pipe diameters upstream/downstream installations with accuracy of 0.4%.

Territory Restriction: Due to our territory agreement with Siemens, Lesman is the authorized Siemens sales representative in Illinois, Indiana, Wisconsin, Eastern Missouri, Michigan's Upper Peninsula, Paducah KY area, Oregon, Washington, Northern Idaho, Western Montana, Alaska, and Hawaii. If you are outside that area, you can find your local sales office or get technical assistance by calling 800-365-8766 or 972-522-4500, or sending an email to piabusales.industry@siemens.com.

Siemens SITRANS FMS500 flow sensors are designed for monitoring flow in water and wastewater applications. It comes standard with corrosion-resistant, epoxy-coated carbon steel body, Hastelloy C-276 integrated grounding and measuring electrodes, and EPDM or NBR liner, and is available in sizes from 1/2" to 48" diameters.

The FMS500 coned liner design provides increased low flow accuracy for water leak detection. The rugged unit suitable for direct burial and constant flooding, and when ordered with an EPDM liner, can be used for drinking water applications.

Key applications include water abstraction, water and wastewater treatment, water distribution and leak detection, custody transfer water meters, irrigation, filtration, and industrial water applications.

  • Range: 0 to 10 m/Sec
  • Sensor diameters from 0.5" to 48" (DN 15 to DN 1200)
  • Accuracy: 0.4% of flow rate standard; 0.2% of flow rate optional
  • Independently tested by Force Certification to be installed in zero diameter upstream, zero diameter downstream straign run pipe installations and maintain accuracy of 0.8%
  • Suitable for operating pressures to 580 PSI, and media temperatures from 14° to 158° F (-10° to 70° C).
  • Liner materials available in EPDM and NBR
  • Hastelloy C-276 integrated grounding and measuring electrodes – no grounding rings required for many applications
  • NEMA 6P/IP68 steel sensor housing with corrosion-resistant epoxy coating
  • Drinking water approvals available
  • Calibrated in ISO / IEC 17025 accredited facility

 