Honeywell's 12" circular chart recorder, ±0.05% full scale accuracy, prints its own graph grid, scales, timestamps, recorder ID header, pen ID marks and up to four inputs (pens) on thermal paper with one black and white stylus. Comes with digital display and keyboard, communications, control outputs, alarms and digital inputs, totalization, and math options.
Honeywell's DR4500 Truline 12" circular chart recorder with 0.05% accuracy gives you the most complete chart documentation of your process data. It provides the the exact data you want, written on a blank thermal chart. Your desired reference grid is drawn the same time it records your trend data, so there's no need to buy different chart paper if your recording timeframe or range changes..
Multiple different-ranged chart scales are printed easily, avoiding the problems of special-order chart paper for multichannel recording. There is no skew or time offset between pens; all simultaneous pen data points are printed on the same time line. Because the grid prints with your data, you'll see zero error from chart shrinkage or swelling caused by humidity in your process environment. Alphanumeric printing for your chart's header ID includes chart tag name, start time and date, pen range and units, and rotation rate. Major time divisions are identified with an hour:minute or day:hour printout.
There's a Truline model that's suited for your specific industry: food, water and wastewater treatment, pharmaceutical, dairy, environmental testing, and metal-working. Even the FDA agrees: Truline AH, AS, and AP models comply with 3A sanitary standards for use as pasteurization flow recorder/controllers, and meet the Grade "A" Pasteurized Milk ordinance.
- Accuracy to ±0.05% span
- Prints from up to four inputs with a single thermal stylus
- Prints data and timestamps on a user-configured thermal chart as it records; Can include six-character event message
- One or two control loops: Full PID control, full range of outputs
- Ramp-soak setpoint programming option
- Digital communications over RS-485 Modbus RTU interface
- Up to six Form C alarm relays
- Optional math and Fo sterilization calculations
- Capable of performing open channel flow calculations for flumes
- One to four totalizers, prints total on the chart at major time divisions
- Menu configuration with display and keyboard: no software needed
- Kit includes recorder, mounting brackets, pack of 100 blank thermal charts, printed quick start guide, CD documentation
Looking for a replacement pen arm? Not sure which one you have? Take a look at your recorder, to the pen arm tip closest to the stylus. If the tip is black, you need the standard pen arm (30756304-501). If the tip is white, you're using the abrasion-resistant pen arm (30756304-502).
Model Selection Guide
Need replacement parts for an existing Truline recorder? Call Lesman with your model and serial number. We'll help find what you need. In-stock recorders and parts ordered from Lesman stock ship within a single business day.
Use this table to find the right model for your application. Make one selection from each table section to build your completed recorder catalog number. Not all options are available on all Truline models. Please refer to the appropriate specification datasheet under Product Literature for complete details.
A complete model number looks like this: DR45A_- _ _ _ _ - _ _ - _ _ _ - _ - _ _ _ _ _ _ -0
Description | Model Number | |
---|---|---|
Truline 12" Circular Chart Recorder | Standard Model Relay Expansion Model Flow Recorder HTST (High Temperature/Short Time) Model Pasteurization Flow Recorder Safety Thermal Limit Recorder |
DR45AT- DR45AR- DR45AW- DR45AH- DR45AP- DR45AS- |
Table I — Inputs | ||
Channel 1 Input | T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radiamatic 0-10 VDC | 1 _ _ _- 3 _ _ _- |
Channel 2 Input | None T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radiamatic 0-10 VDC | _ 0 _ _- _ 1 _ _- _ 3 _ _- |
Channel 3 Input | None T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radiamatic 0-10 VDC | _ _ 0 _- _ _ 1 _- _ _ 3 _- |
Channel 4 Input | None T/C, RTD, mV, 0-5 VDC, 4-20 mA, Radiamatic 0-10 VDC | _ _ _ 0- _ _ _ 1- _ _ _ 3- |
Table II — External Outputs | ||
Output #1 | None Control Output #1 (for DR45AH, DR45AP) Control Output #1 Pulse Output | 0 _- 1 _- 4 _- 5 _- |
Output #2 | None Control Output #2 (for DR45AP) Control Output #2 | _ 0- _ 1- _ 4- |
Table III — Interface | ||
External Interface | None Auxiliary 4-20 mA Output RS485 Modbus RTU Communications RS485 Modbus RTU and 4-20 mA Output | 0 _ _- 1 _ _- 3 _ _- 4 _ _- |
Pens | Truline High Speed Pen (Black Tip on Stylus End) Abrasion-Resistant Pen (White Tip on Stylus End) | _ 0 _- _ 1 _- |
Alarms and Digital Inputs | None Two Alarms, Two Digital Inputs Four Alarms, Two Digital Inputs Six Alarms, Two Digital Inputs One Alarm, One Timer Output, Two Digital Inputs | _ _ 0- _ _ 1- _ _ 2- _ _ 3- _ _ 4- |
Table IV — Software Options | None Totalization on Input #1 Totalization on Inputs #1, #2 Totalization on All Four Inputs FO Sterilization Calculation Math Totalization (IN#1) plus Math Totalization (IN#1,#2) plus Math Totalization on All Inputs plus Math | 0- A- E- H- F- B- K- L- M- |
Table V — Options | ||
Door and Window Materials | Gray Door with Glass Windows Gray Door with Acrylic Window Blue Door with Glass Window Blue Door with Acrylic Window Stainless Steel Door with Glass Window Stainless Steel Door with Acrylic Window NEMA 4X Door with Glass Window NEMA 4X Door with Acrylic Window NEMA 4X Door, HTST, Divert Lights (AH/AP/AS Only) | 0 _ _ _ _ _-0 1 _ _ _ _ _-0 5 _ _ _ _ _-0 6 _ _ _ _ _-0 2 _ _ _ _ _-0 3 _ _ _ _ _-0 P _ _ _ _ _-0 R _ _ _ _ _-0 S _ _ _ _ _-0 |
Latch and Lock | Standard Door Latch Keyed Latch (Standard on AH/AP/AS) Door Lock with Key | _ 0 _ _ _ _-0 _ A _ _ _ _-0 _ K _ _ _ _-0 |
Security | None Configuration Lockout and Chart Plate Seal Configuration Lockout, Chart Plate Seal, Chart Illumination Chart Illumination | _ _ 0 _ _ _-0 _ _ L _ _ _-0 _ _ M _ _ _-0 _ _ N _ _ _-0 |
Agency Approvals | None CE CE, UL, CSA CE, FM Approval CE, UL, CSA, and FM Approval UL, CSA FM Approved Class I, Div 2, Groups A-D UL, CSA, and FM Approval | _ _ _ 0 _ _-0 _ _ _ K _ _-0 _ _ _ L _ _-0 _ _ _ M _ _-0 _ _ _ N _ _-0 _ _ _ P _ _-0 _ _ _ R _ _-0 _ _ _ U _ _-0 |
Documents and Tags | None Customer ID Tag (30 Characters Max) F3391 Certificate of Conformance F3399 Calibration Test Report F3391 Certificate of Conformance and ID Tag F3399 Calibration Test Report and ID Tag | _ _ _ _ 0E-0 _ _ _ _ TE-0 _ _ _ _ BE-0 _ _ _ _ CE-0 _ _ _ _ DE-0 _ _ _ _ EE-0 |
Accessories | Pack of 100
Truline Thermal Charts Replacement Standard (Black Tip) Pen Arm Replacement Abrasion-Restant (White Tip) Pen Arm | 30755317-001 30756304-501 30756304-502 |
To build your complete part number, make a selection from each table section below. Your completed model and its price will appear below the table. If you don't see the options you need, call us.