Full DIN size single or dual input analyzer/controller for combination of pH, ORP, contacting conductivity or dissolved oxygen. Up to three analog outputs, up to four alarm relays, RS-485 Modbus and Ethernet web server communications. CE, CSA, FM, UL approvals.
Honeywell's UDA2182 series is a versatile dual-input analyzer that measures pH/ORP, contacting conductivity, and dissolved oxygen in demanding applications in the power generation water quality control, wastewater treatment influent and effluent, pure water preparation and neutralization for food and beverage, pharmaceutical, and chemical industries.
The UDA2182 accepts inputs from Honeywell Durafet and Meredian pH and ORP electrodes plus the HPW7000 high purity water system, Honeywell's contacting conductivity cells, and the Honeywell dissolved oxygen equilibrium probe for ppm or ppb measurement. Its mix-and-match design means you can stock fewer devices for your applications, and easily field-modify when your applications change.
- Single or dual input analyzer for liquid processes
- Mix and match process measurements in one analyzer: pH, ORP, conductivity, and dissolved oxygen
- PID, duplex and on/off control with Honeywell AccuTune II autotuning and fuzzy logic overshoot suppression
- Two analog outputs standard (plus one optional), up to four electromechanical high/low alarm relays
- Graphic LED displays two process variables, process temperature of both PVs, analog output full scale percentage, state of relays, tagging, time or date information plus status messages
- Ethernet and RS-485 Modbus communications available
- Wireless infrared port for setup using Honeywell Process Instrument Explorer software
- Direct replacement for retired Honeywell (L&N) 7082, Honeywell 9782P/C and Honeywell 7021/7022 process analyzer models
- Type 4X/NEMA 4 full DIN enclosure with panel, wall, or pipe mounting
- CE, CSA, FM approvals, UL listing
Model Selection Guide
Use this table to find the right model for your application. Don't see the option you need? Call a Lesman sales specialist at 800-953-7626.
Description | Catalog Number |
|
---|---|---|
UDA2182 Multifunction Analyzer:
Two 4-20 mA outputs, two alarm relays, panel mount hardware, and IrDA port |
UDA2182 - | |
Channel 1 Input | pH/ORP pH from Preamp Conductivity Dissolved Oxygen ppm Dissolved Oxygen ppb |
PH1 - PA1- CC1- DM1- DB1- |
Channel 2 Input | None pH/ORP pH for Preamp Conductivity Dissolved Oxygen ppm Dissolved Oxygen ppb |
NN2 - PH2- PA2- CC2- DM2 DB2 |
Outputs and Relays | None +(1) 0/4-20 mA Output + 2 Relays |
NN - C3- |
Communications | None Serial Input: Ethernet/Modbus |
N - E - |
Mounting Hardware | None (Panel Mount Only) Pipe and Wall Mount |
0 _ _ _ P _ _ _ |
Manual | Printed Instruction Manual | _ E _ _ |
Certificates | None Calibration and Conformance |
_ _ 0 _ _ _ C _ |
PID Control | None Yes (See Note) |
_ _ _ 0 _ _ _ C |
Accessories | Process Instrument Explorer Software | 50001619-001 |
Actisys Serial to Infrared Adapter for PCs | ACT-IR220L+ | |
Bezel Assembly | 51453518-502 | |
Input Card: pH/ORP Measurment | 51453313-501 | |
Input Card: pH from Preamp | 50009551-501 | |
Input Card: Contacting Conductivity | 51453316-501 |
Note:
Includes Auto Clean/Cal, USP26 Pure Water Functionality and pH Level/CO2
Concentration from Differential Conductivity
To build your complete part number, make a selection from each table section below. Your completed model and its price will appear in the Results section. If you don't see the options you need, call us.