Prices starting at:
Price
$97.00
Call for Availability
SKU
84447XXX
The Honeywell Kromschroder DG pressure switches are able to monitor extremely low pressure differentials, positive and negative gas pressure on industrial gas and air appliances, and biologically produced methane.
Featuring the ability to observe extremely low pressure differentials, Honeywell Kromschroder's DG pressure switches trigger switch-on, switch-off, switch-over operations if a set switching point is reached. They monitor positive and negative gas and air pressures in industrial and commercial applications.
- Applications in monitoring positive air and gas pressures, negative or differential air pressures
- Five pressure ranges from 0.2" to 200" WC", does not apply for all switches
- Max inlet pressure rating: 8.5 PSIG with venting line installed, 7.0 PSIG without venting line
- Accurate, repeatable switching action with low hysteresis
- Automatic and manual reset models available
- One normally open and one normally closed contact in each switch (5A resistive or 0.5A inductive)
- 8A quick-acting fuse for short circuit protection
- FM and UL approved
- Lesman stocks most ranges and configurations of Honeywell Kromschroder DG pressure switches. In-stock models are available to ship the same day.
Model Selection Guide
Don't see the option or pressure range you need? Call a Lesman sales specialist at 800-953-7626.
Switch Operation | Break Action | Pilot Lamp | Process
Connection | Electrical Connection | Adjustable Range | Designation | Click for Price and Availability |
---|---|---|---|---|---|---|---|
DG..T pressure switch for positive, negative, or differential pressure. Dual scale "WC and mBar. Hand-wheel adjustable switch point. FM/UL Tested. IP54 | |||||||
Auto Reset | Switches on pressure rise | Blue pilot lamp
for 110/120 VAC | 1 x 1/4" NPT | Screw terminals,
1/2" NPT conduit | 0.2" to 2.4" WC | DG 6T-21N | KS84447800 |
0.4" to 4" WC | DG 10T-21N | KS84447810 | |||||
1" to 20" WC | DG 50T-21N | KS84447820 | |||||
12" to 60" WC | DG 150T-21N | KS84447830 | |||||
40" to 200" WC | DG 500T-21N | KS84447840 | |||||
DG..T pressure switch for positive, negative, or differential pressure. Hand-wheel adjustable switch point. FM/UL Tested. IP54 | |||||||
Auto Reset | Switches on pressure rise | Blue pilot lamp
for 110/120 VAC | 2 x 1/4" NPT | Screw terminals,
1/2" NPT conduit | 0.2" to 2.4" WC | DG 6T-22N | KS84447802 |
0.4" to 4" WC | DG 10T-22N | KS84447812 | |||||
1" to 20" WC | DG 50T-22N | KS84447822 | |||||
12" to 60" WC | DG 150T-22N | KS84447832 | |||||
40" to 200" WC | DG 500T-22N | KS84447842 | |||||
DG..TG pressure switch for positive, negative, or differential pressure. Gold-plated contacts. Hand-wheel adjustable switch point. FM/UL Tested. IP54 | |||||||
Auto Reset | Switches on pressure rise | Green/red pilot lamp
for 24 VAC/VDC | 2 x 1/4" NPT | Screw terminals,
1/2" NPT conduit | 0.2" to 2.4" WC | DG 6TG-22K2 | KS84447803 |
0.4" to 4" WC | DG 10TG-22K2 | KS84447813 | |||||
1" to 20" WC | DG 50TG-22K2 | KS84447823 | |||||
12" to 60" WC | DG 150TG-22K2 | KS84447833 | |||||
40" to 200" WC | DG 500TG-22K2 | KS84447843 | |||||
DG..HT pressure switch for positive, negative, or differential pressure with manual reset. FM/UL Tested. IP54 | |||||||
Manual Reset | Locks on pressure rise | Blue pilot lamp for 110/120 VAC | 2 x 1/4" NPT | Screw terminals,
1/2" NPT conduit | 0.4" to 4" WC | DG 10HT-22N | KS84447912 |
1" to 20" WC | DG 50HT-22N | KS84447922 | |||||
12" to 60" WC | DG 150HT-22N | KS84447932 | |||||
40" to 200" WC | DG 500HT-22N | KS84447942 | |||||
DG..NT pressure switch for positive, negative, or differential pressure with manual reset. FM/UL Tested. IP54 | |||||||
Manual Reset | Locks on pressure fall | Blue pilot lamp for 110/120 VAC | 2 x 1/4" NPT | Screw terminals,
1/2" NPT conduit | 0.4" to 4" WC | DG 10NT-22N | KS84447962 |
1" to 20" WC | DG 50NT-22N | KS84447972 | |||||
12" to 60" WC | DG 150NT-22N | KS84447982 | |||||
40" to 200" WC | DG 500NT-22N | KS84447992 | |||||
DG..U pressure switch for positive, negative, or differential pressure. Hand-wheel adjustable switch point. EU certified. IP54 | |||||||
Auto Reset | Switches on pressure rise | Screw terminals and
M16 cable gland | 0.4 to 6 mBar | DG 6U-3 | KS84447250 | ||
1 to 10 mBar | DG 10U-3 | KS84447300 | |||||
2.5 to 50 mBar | DG 50U-3 | KS84447350 | |||||
30 to 150 mBar | DG 150U-3 | KS84447500 | |||||
DG..UG pressure switch for positive, negative, or differential pressure. Gold-plated contacts. Hand-wheel adjustable switch point. EU certified. IP54 | |||||||
Auto Reset | Switches on pressure rise | Screw terminals and
M16 cable gland | 0.4 to 6 mBar | DG 6UG-3 | KS84447270 | ||
1 to 10 mBar | DG 10UG-3 | KS84447320 | |||||
2.5 to 50 mBar | DG 50UG-3 | KS84447370 | |||||
30 to 150 mBar | DG 150UG-3 | KS84447520 | |||||
100 to 500 mBar | DG 500UG-3 | KS84447570 | |||||
DG..UG pressure switch for positive, negative, or differential pressure. Gold-plated contacts. Hand-wheel adjustable switch point. EU certified. IP65 | |||||||
Auto Reset | Switches on pressure rise | Screw terminals and
M16 cable gland | 0.4 to 6 mBar | DG 6UG-4 | KS84447000 | ||
1 to 10 mBar | DG 10UG-4 | KS84447010 | |||||
2.5 to 50 mBar | DG 50UG-4 | KS84447020 | |||||
30 to 150 mBar | DG 150UG-4 | KS84447030 | |||||
100 to 500 mBar | DG 500UG-4 | KS84447040 | |||||
DG..UG pressure switch for positive, negative, or differential pressure. Gold-plated contacts. Hand-wheel adjustable switch point. EU certified. IP65 | |||||||
Auto Reset | Switches on pressure rise | Green/red pilot lamp for 24 VAC/VDC | Screw terminals and
M16 cable gland | 0.4 to 6 mBar | DG 6UG-4K2 | KS84447001 | |
1 to 10 mBar | DG 10UG-4K2 | KS84447011 | |||||
2.5 to 50 mBar | DG 50UG-4K2 | KS84447021 | |||||
30 to 150 mBar | DG 150UG-4K2 | KS84447031 | |||||
100 to 500 mBar | DG 500UG-4K2 | KS84447041 | |||||
DG..UT pressure switch for positive, negative, or differential pressure. Hand-wheel adjustable switch point. EU certified. IP54 | |||||||
Auto Reset | Switches on pressure rise | Green/red pilot lamp for 230 VAC/VDC | 4-Pin plug and socket | 2.5 to 50 mBar | DG 50U-6T2 | KS84447388 | |
30 to 150 mBar | DG 150U-6T2 | KS84447514 | |||||
100 to 500 mBar | DG 500U-6T2 | KS84447564 |
Measured Variable | Differential Pressure, Gauge Pressure |
---|---|
Enclosure/Construction | IP54 |
Sensor Type | Diaphragm |
Adjustment | External Adjustment |
Measuring Range | 0.2" to 200" WC (0.4 to 500 mbar) |