$500+ Orders on Lesman.com Ship Free via UPS Ground
Eurothern's EPC3000 programmable single loop process and temperature controllers deliver fast acting and repeatable control. They come standard with Ethernet connectivity providing fast access to process and diagnostic information as well as connectivity to external PLCs, SCADA systems, and IIoT designs. They are certified to meet the stringent cybersecurity requirements of Achilles® Communications Robustness Testing Level 1. Available in 1/4 DIN, 1/8 DIN, and 1/16 DIN cutouts with multiline digital displays and front-panel programming buttons.
Process inputs are fast and accurate, with exceptional thermal stability, aiding precise and consistent control over long periods without calibration drift. Recalibration and user calibration correction functions are available to further improve accuracy.
- Display Type High Visibility LCD three color multifunction display, 3008/3004 4.5,5 Digit PV, 2 starburst, 3016 4 Digit PV, 1 starburst
- Safety-approvals Achilles CRT Level 1 Cybersecurity, EN13849 PLc, EN14597 TR, Factory Mutual (FM) approved
- Input Type TC, PT100/PT1000 RTD, mV, mA, Zirconia
- PV Accuracy <0.1% low thermal drift
- Control Types On/Off, PID, VP, Carbon Potential
- Special Features Application Templates, Atmosphere Control, Gain Scheduling, Maths and Totalizer Function, Native Ethernet, Recipes, Text Messaging, Dual input control
- SP Programmer Up to 20 programmes of 8 segments or 10 programmes of 24 segments
- Analogue IP/OP 3008/3004: 2PV, 1CT, 3 Isolated DC OP, 3016: 1PV, 1CT, 1 Aux (RSP), 2 Isolated DC OP, In 4, Out 3
- Digital IP/OP 8 (max) Open Collector DIO 3008/3004, In 5, Out 4
- Digital Comms BACNet, EIA-485, EtherNet/IP, Modbus RTU, Modbus TCP
- Alarm Types Hi, Lo, Dev, Sensor fault, Heater fail, Rate of Change, Event
Model Selection Guide
Make one selection from each table section below. Follow the arrows down to make sure the option you want is available. A complete model number could look like this: EPC3004/CC/VH/XX/XX/XX/XX/XX/XX/XX/XX/XXX/ST/XXXXX/XXXXXX/XX/X/X/X/X/X/X/X/X/X/X/XX/XX/XX.
EPC3016: Includes one Universal PV Input and one Form C Relay. EPC3008/3004: I/O supplied as standard includes one Universal PV Input, EIA-485 Modbus RTU Slave Communications, 1 Form C Relay, 2x Contact Closure Digital Inputs, 1 Current Transformer Input, and 24Vdc Transmitter Power Supply.
Don't see what you need? Call our factory automation specialists at 800-225-6102.
Description | Catalog Number | Availability | |||
---|---|---|---|---|---|
Controller Model | 1/4 DIN Controller, EPC3004 | EPC3004 | ↓ | ||
1/8 DIN Controller, EPC3008 | EPC3008 | ↓ | |||
1/16 DIN Controller, EPC3016 | EPC3016 | ↓ | |||
Type | Controller only | CC | ● | ● | ● |
1 X 8 Segment Basic Programmer | CP | ● | ● | ● | |
1 X 24 Segment Advanced Programmer | P1 | ● | ● | ● | |
FM Alarm Unit | FM | ● | ● | ● | |
Supply Voltage | 100-230 VAC | VH | ● | ● | ● |
24VAC/24 VDC | VL | ● | ● | ● | |
I/O 1 | Not Fitted | XX | ● | ● | ● |
Relay Output (without snubber) | R1 | ● | ● | ● | |
DC Output | D1 | ● | ● | ● | |
Triac (without snubber) | T1 | ● | ● | ● | |
I/O 2 | Not Fitted | XX | ● | ● | ● |
Relay Output (without snubber) | R1 | ● | ● | ● | |
DC Output | D1 | ● | ● | ● | |
Triac (without snubber) | T1 | ● | ● | ● | |
I/O 4 | Not Fitted | XX | ● | ● | ● |
Relay Output (without snubber) | R1 | ● | ● | ||
DC Output | D1 | ● | ● | ||
Triac (without snubber) | T1 | ● | ● | ||
Output 3 | Form C (Default) | XX | ● | ● | ● |
Serial Communications | ModBUS slave (Default) | XX | ● | ● | ● |
ElBiSync Enabled | EI | ● | ● | ● | |
Modbus Master | SM | ● | ● | ● | |
Ethernet, 2nd Input, I/O Options | None (Default) | XX | ● | ● | ● |
Second PV Input, 8 Digital Input/Outputs | I8 | ● | ● | ||
Ethernet TCP Protocol | Ethernet (Modbus TCP Slave) 4 X Digital I/O Only | E4 | |||
Modbus TCP Slave or None | XX | ● | ● | ● | |
Ethernet/IP Server | ES | ● | ● | ● | |
Tool Kit Blocks | None (Default) | XX | ● | ● | ● |
Standard | TK | ● | ● | ● | |
OEM Security | None | XXX | ● | ● | ● |
OEM Security | OEM | ● | ● | ● | |
Bezel | Standard IP65/NEMA 12 | ST | ● | ● | ● |
Washdown IP66/NEMA 4X (Indoor Use) | WD | ● | ● | ● | |
Labels | XXXXX | XXXXX | ● | ● | ● |
Specials | XXXXXX | XXXXXX | ● | ● | ● |
Gain Scheduling Sets | Two Gain Scheduling Sets (Standard) | XX | ● | ● | ● |
Eight Gain Scheduling sets | 08 | ● | ● | ● | |
Application | Heat Only (default) | 1 | ● | ● | ● |
Heat/Cool | 2 | ● | ● | ● | |
FM High Limit | H | ● | ● | ● | |
Input 1 Sensor Type | Linear 0-10VDC | V | ● | ● | ● |
Linear 4-20mA | 4 | ● | ● | ● | |
Type J Thermocouple | J | ● | ● | ● | |
Type K Thermocouple | K | ● | ● | ● | |
PT100 RTD | P | ● | ● | ● | |
PT1000 RTD | W | ● | ● | ● | |
Input Range 1 | Full Range | F | ● | ● | ● |
Input 2 Sensor Type | Not Fitted | X | ● | ● | ● |
Type J Thermocouple | J | ● | ● | ||
Type K Thermocouple | K | ● | ● | ||
Input Range 2 | Not Fitted | X | ● | ● | ● |
Full Range | F | ● | ● | ||
Current Input Range | Not Used | X | ● | ● | ● |
10A | 1 | ● | ● | ● | |
50A | 5 | ● | ● | ● | |
100A | 6 | ● | ● | ● | |
Digital Input A Function | Not Used | X | ● | ● | ● |
Auto/Manual | M | ● | ● | ● | |
Local Setpoint Select | P | ● | ● | ● | |
Remote Setpoint Select | U | ● | ● | ● | |
Digital Input B Function | Not Used (EPC3004/EPC3008) | X | ● | ● | |
Not Used (EPC3016) | XX | ● | |||
Auto/Manual | M | ● | ● | ||
Programmer I/O Config | Not Used/Fitted (EPC3004/EPC3008) | X | ● | ● | |
Not Used/Fitted (EPC3016) | XX | ● | |||
Units | Degrees Fahrenheit | F | ● | ● | ● |
Future | Future | XX | ● | ● | ● |
Warranty | Standard Warranty | XX | ● | ● | ● |
Certificate of Conformity | None Required | XX | ● | ● | ● |